These three come up constantly in inspection reports and they get lumped in with Federal Pacific and Zinsco, which is not quite fair to them. The honest case for replacing one is different — it is about parts that no longer exist, panels with no main switch, and age — and it is strong enough without borrowing anybody else's statistics.

About this article
Author: Branden Hustedqualifying contractor on Sunrise’s CSLB-licensed C-10 (Electrical) classification, license #C10-1097237, Founder, Sunrise Electrical Contracting Inc.
Published: August 3, 2026 · Last reviewed: August 6, 2026
Sources: U.S. Consumer Product Safety Commission — recall database search · California Electrical Code (Title 24, Part 3) — 2025 edition, effective January 1 2026 · Santa Cruz County Building Division — permit authority
Editorial standards: /editorial-standards · Corrections: /corrections-policy
Conflict of interest: Sunrise provides the services this guide describes; we have a financial interest in some recommendations. We mitigate this with the editorial standards linked above.

Quick answer — the 30-second version

  • There is no published failure-rate research on these comparable to what exists for Federal Pacific and Zinsco, and this page does not invent any. What we can tell you is what we find: these panels are all now fifty years old or more, we see problems in them routinely, and age by itself is a condition — contacts, bus and terminations do not improve with time. Treat "obsolete" as the starting point rather than the verdict.
  • The real case for replacement is practical: no new breakers are manufactured, so replacements are salvage or refurbished, and a panel you cannot add a circuit to blocks everything else you might want to do.
  • Many Pushmatic and Wadsworth panels are SPLIT-BUS — no single main breaker, so nothing turns the whole house off at once. That matters in an emergency and when work needs doing.
  • Whether yours needs replacing is a per-panel assessment: condition, bus and terminations, split-bus or not, capacity against your plans, and what your insurer says. Usually yes. And one thing is not a judgement call — we do not add new circuits to these panels, whatever their condition. If your project needs a new circuit, it needs a panel first.
03·The full explanation

Why these three are a different conversation

Federal Pacific and Zinsco have a body of published research and regulatory attention behind the concern about them, which is why our guides on those two brands cite specific figures and why the recommendation there is direct. Pushmatic, Challenger and Wadsworth do not have an equivalent evidence base. Anyone quoting failure rates for these three is either borrowing numbers from the other brands or repeating something from the trade internet that traces back to nobody.

We are not going to do that, and it costs the argument nothing — because the case for replacing an obsolete panel does not rest on how often it fails. It rests on the fact that you cannot buy a part for it, that many of them cannot be switched off in one movement, and that they have been in service for forty to sixty years in a coastal climate. Those are checkable facts about your specific panel rather than a claim about a brand.

The parts problem, which is the real one

All three lines are out of production and have been for a long time. What exists is salvaged stock and refurbished units through specialist suppliers, which creates two distinct problems.

The first is a blocking problem. Adding a circuit means adding a breaker, and if breakers are not available then the panel is the reason you cannot have a charger, a heat pump circuit, a new kitchen or a sub-panel for the garage. Plenty of people meet their panel for the first time this way — not because anything went wrong, but because they wanted to add something and the panel said no.

The second is a quality problem. A breaker is a safety device whose entire purpose is to work correctly the one time it matters. Replacing a failed one with a used unit of unknown age, unknown storage history and unknown number of operations is not a satisfying answer, and refurbished does not mean tested to the standard a new device is manufactured to. On a sub-panel feeding a shed this is an acceptable compromise. On a main panel it is not one we would propose as a plan.

Split-bus panels and the missing main switch

This one surprises people, and it is worth understanding because it changes what you can do in an emergency.

A modern panel has a main breaker: one switch, at the top, that disconnects everything below it. Many older panels — including a large share of Pushmatic and Wadsworth installations — are SPLIT-BUS instead. The top section holds several large breakers feeding the major loads directly, and one of them feeds the lower section where the lighting and general-purpose circuits live. There is no single disconnect.

  • Nothing turns the whole house off in one movement, and working out which combination does is not something to be doing under pressure
  • The panel cannot be cleanly de-energised for work on it, which affects how any repair has to be approached
  • The design predates modern expectations about service disconnects, and it is one of the reasons these panels read as obsolete to an inspector at a glance
  • It is also why our advice about switching off the main during an emergency needs a caveat in these houses — there may not be one to switch

What we actually assess

Brand is where the conversation starts, not where it ends. What decides the recommendation is the panel in front of us.

  • BUS CONDITION — corrosion, pitting, and any evidence of heat at the stabs where breakers connect. Near the coast this is the finding that most often settles it
  • TERMINATIONS — whether connections are tight, whether anything has been overheating, whether previous work was done properly
  • SPLIT-BUS or a proper main disconnect
  • BREAKER OPERATION — Pushmatic mechanisms in particular stiffen when they have not been operated for decades, and a breaker that is reluctant to move is a breaker whose behaviour under fault is unknown
  • CAPACITY against what you are planning to add, which is a separate question from condition and often the one that actually decides the timing
  • THE SERVICE around it — an obsolete panel on a service that is itself due work is a different proposition from one on a sound modern service

Sometimes the honest answer is that the panel is in reasonable condition and the pressure to replace it is coming from a plan to add load rather than from the panel itself. That is worth knowing, because it changes the timing and sometimes the sequence — and because a written assessment saying so is useful when a carrier or a buyer asks.

What replacement involves here

Every main panel job we do is a full electrical service rebuild, whether it is an upsize or a like-for-like replacement at the same amperage. The service entrance conductors, the combination meter main, and the grounding and bonding all come up to current code alongside the new panel, breakers and a whole-house surge protector. This is worth saying plainly, because quotes that describe swapping the box for a smaller number are describing a smaller job than the one that has to happen.

On an OVERHEAD service the chain is weatherhead, mast, service entrance conductors, combination meter main, grounding. On an UNDERGROUND service there is no mast or weatherhead — the utility conductors come to a service point and terminate inside the combination meter main — and a like-for-like still needs PG&E to disconnect and reconnect at the splice. On an underground upsize the largest cost variable is whether existing conduit is two inches or larger and reusable, or whether new conduit has to be trenched; we assess the visible conduit when quoting, PG&E verifies after contract, and we requote if they require new conduit rather than springing it on you mid-job.

Most of these are a single day. PG&E disconnects, we rebuild, the AHJ inspects, PG&E reconnects, and you are without power for the working portion of the day — worth planning around if somebody works from home or there is medical equipment in the house. The panel we fit is Siemens unless you ask for another brand, and breakers always match whichever panel goes in, because mixing makers voids the UL listing of the assembly regardless of physical fit.

If yours is showing symptoms, stop reading

Everything above is a planning conversation. A panel that smells of burning, feels warm through the cover, makes noise, or has visible scorching is not a planning conversation. Switch off what you can safely reach, do not open the cover, and call. Obsolete brand or not, heat at a panel is heat at the connections that feed the whole house.

04·Is this you?

Two ways to check. Both take a minute.

Checklist · tap what’s true

Check what applies to your panel. Two or more usually means replacement is the practical answer rather than an optional one.

Or — show us a photo

A photo of the panel with the cover ON, plus the label showing the brand and the main rating, is enough for us to tell you what you are dealing with. Do not remove the cover.

Email us a photo
A clear photo of the panel and the brand label is enough — JPG, PNG or HEIC.
06·Pricing transparency

Every quote is free. The range depends too much on your home to fake it.

We do not publish a figure for this, because the honest range depends on things nobody can see from a brand name — overhead versus underground, whether existing conduit is reusable, panel location and access, whether the service is being upsized at the same time, and which AHJ issues the permit. What is consistent is the scope: every main panel job is a full service rebuild including the service entrance conductors, the combination meter main, grounding and bonding, the new panel and breakers, a whole-house surge protector, permit and inspection coordination, and the 20-year workmanship warranty. We quote the exact number in writing after a free look. Cost ranges are pulled from real Santa Cruz County job data at render, not made up here.

Financing · GoGreen Home
GoGreen Home financing applies when the panel work is tied to a qualifying energy-efficiency upgrade — an EV charger, a heat pump, a heat-pump water heater, induction, or solar with battery. Replacing an obsolete panel on its own does not qualify. An obsolete panel is often exactly what stands between somebody and one of those upgrades, so it frequently does apply, but confirm rather than assume.
Pre-qualify in 60 seconds — no credit impact
What it costs
Quotes are free.The variance on this work is too wide for an honest range — book a free inspection and we’ll give you a real number for your specific home, in writing.
What moves the number
Overhead versus underground service · Underground: existing 2"+ conduit reusable, or new conduit trenched · Whether the service is being upsized or replaced like-for-like · Panel location and accessibility, including split-bus rework · Which AHJ issues the permit (Santa Cruz, Capitola, Scotts Valley, Watsonville, or unincorporated County) · Coastal corrosion-zone hardware for homes near the ocean
No hidden fees. Every quote is free and detailed.
07·What to do next
When you’re ready

Photograph the label, then decide with an assessment rather than a brand name.

Send a photo of the panel with the cover on and the label showing the brand and main rating. That tells us whether you are looking at a split-bus design, roughly what era it is, and whether breakers are obtainable. If you are planning to add load, have the capacity calculation done at the same time — the two questions decide each other more often than not. And if there is any smell, warmth or scorching, none of this applies: switch off what you can reach safely and call.

08·Even if Sunrise isn't the answer

Here’s the honest path — wherever it leads.

We'd rather you get the right outcome than the Sunrise outcome. Some of this points away from us on purpose.

Get it assessed, not guessed

A free whole-home inspection covers the panel condition, the bus and terminations, and a load calculation against what you plan to add. You keep the written report — useful if an insurer or a buyer is the one asking.

Schedule a free inspection

Smell, warmth or scorching?

That is not a planning question. Switch off what you can safely reach, do not open the cover, and call. In a split-bus panel there may be no single main to switch, so switch off what you can identify.

I smell burning. What do I do?

Outside Santa Cruz County?

Find a CSLB-licensed C-10 contractor and verify at cslb.ca.gov. Ask whether the quote covers the service entrance conductors, the meter main and the grounding — and be wary of anyone quoting failure statistics for these three brands, because the sourced research is about Federal Pacific and Zinsco.

10·Frequently asked questions

15 questions. Real answers.

The questions readers actually ask about this specific problem, answered in full.

Are Pushmatic panels dangerous?
Not in the way Federal Pacific and Zinsco are usually described, and it matters to be precise about that. Pushmatic breakers were solidly built and there is no body of published failure-rate research on them comparable to what exists for those two brands. What is true is that they are long obsolete, that the mechanisms stiffen with age and disuse, that new breakers are not manufactured so replacements are salvage or refurbished units, and that many Pushmatic installations are split-bus with no single main disconnect. That is a real case for replacement without needing to overstate it.
What is a split-bus panel and why does it matter?
A split-bus panel has no single main breaker. Instead the top section holds several large breakers feeding the major circuits, one of which feeds the lower lighting-and-appliance section. The practical consequence is that there is no one switch that kills the whole house — you have to switch off several, and knowing which is not obvious in an emergency. It also means the panel cannot be shut down cleanly for work on it. Many Pushmatic and Wadsworth panels are built this way.
Can I still buy breakers for these panels?
Not new. All three lines are out of production, and what is available is salvaged or refurbished stock through specialist suppliers. That is the practical heart of the problem: a panel you cannot add a circuit to is a panel that blocks everything else you might want to do to the house. It also means a failed breaker gets replaced with a used one of unknown history, which is not a satisfying answer on a device whose entire job is to fail safe.
Has any of these been recalled?
Recall status is specific to particular products and dates rather than to a brand name, and it is exactly the sort of claim that circulates in confidently wrong forms. The reliable way to check is the Consumer Product Safety Commission's own database at cpsc.gov, searching the brand and the model from your panel label. If you send us a photo of the label we will check it with you.
My home inspector flagged the panel. Does that mean it has to go?
It means it needs assessing rather than that a verdict has been reached. Inspectors flag obsolete brands as a matter of routine because they cannot verify parts availability or condition from a visual check, which is the correct professional caution. Whether yours needs replacing depends on its actual condition, whether it is split-bus, whether the service is adequate for what you plan to add, and what your insurer says. Those are four separate questions and the answer is usually yes. One part is not a judgement call, though: we will not pull a new circuit off a Pushmatic, Challenger or Wadsworth panel, regardless of how it looks. That is company policy rather than a code rule — after enough years of opening these up, we are not willing to hang new work on equipment we cannot get parts for and cannot vouch for. So if your project needs a circuit added, replacing the panel is not an upsell, it is the first step.
Will my insurance company care?
Some carriers ask about panel brands at renewal or when writing a new policy, and the obsolete lines come up more than modern ones. Positions differ between carriers and change over time, so the only reliable answer is the one your own carrier gives in writing. If a carrier has raised it with you, say so when we come out — a written assessment of the panel is often what they actually want, and it is part of a free inspection either way.
Is a Wadsworth panel worth keeping?
Wadsworth panels have a reputation among electricians for having been well made, and that reputation is largely deserved. It does not change the arithmetic. The company has been gone for decades, the panels are typically pre-1970, breakers are salvage-only, and many are split-bus. A well-made panel that no part is manufactured for is still a panel you cannot safely extend.
What about Challenger?
Challenger panels are generally newer than the other two — largely a 1980s installation — which means the surrounding service is often newer as well and sometimes adequate. They come up frequently in inspection reports. As with the others, we assess the specific panel: bus condition, terminations, evidence of heat, whether breakers are still obtainable, and whether the capacity suits what you are adding. We are not going to repeat brand-level failure claims about it that we cannot source.
Can you just replace the breakers instead of the panel?
Only with used or refurbished units, which we will not do as a considered plan on a main panel. Beyond the unknown history of a salvaged breaker, breakers have to match the panel to keep the UL listing of the assembly intact — a breaker from another maker that physically clips onto the bus is not a listed combination regardless of whether it fits. If the panel is otherwise sound and the issue is one failed breaker, we will talk it through, but it is a stopgap and we will say so.
What does the replacement actually involve?
More than swapping the box. Every main panel job we do — an upsize or a like-for-like at the same amperage — is a full electrical service rebuild: the service entrance conductors, the combination meter main, and the grounding and bonding all come up to current code, plus the new panel, breakers and a whole-house surge protector. Most are a single day, with PG&E disconnecting at the start and reconnecting after the inspection.
Do I have to upgrade to 200 amps at the same time?
Not necessarily. Replacing an obsolete panel and increasing service capacity are different decisions that often get made together because the work overlaps. If a load calculation says your existing service covers what you have and what you are adding, a like-for-like replacement at the same amperage is a legitimate answer. It is still a full service rebuild, so the saving is smaller than people expect, but it is a real option.
Which panel would you install?
Siemens, for both main panels and sub-panels, unless you ask for something else — in which case we will fit what you ask for. Breakers always match whichever panel goes in.
Do I need a permit?
Which authority issues a permit depends on your address rather than on the brand of panel: the City of Santa Cruz, Capitola, Scotts Valley and Watsonville each run their own, and everything unincorporated goes through County Planning. Live Oak, Pleasure Point, Soquel, Aptos and Felton are all unincorporated county despite the mailing address. Where a permit applies to work we do, we pull it and coordinate the inspection.
Does financing apply?
GoGreen Home financing applies when the panel work is tied to a qualifying energy-efficiency upgrade — an EV charger, a heat pump, a heat-pump water heater, induction, or solar with battery. Replacing an obsolete panel on its own does not qualify. Since an obsolete panel is often what stands between somebody and one of those upgrades, it frequently does apply in practice, but it is worth confirming rather than assuming.
How do I tell which one I have?
The brand is usually on the panel door, the label inside it, or moulded into the deadfront. Pushmatic is unmistakable once seen — the breakers are push buttons rather than toggles, with no handle to throw. Wadsworth and Challenger are named on the label. Photograph the label and the panel with the cover ON and send it over; do not remove the cover to look for a name.
11·About the author
Written by

Branden Husted · qualifying contractor on Sunrise’s CSLB-licensed C-10 (Electrical) classification, license #C10-1097237

This guide was written by Branden Husted, owner of Sunrise Electrical Contracting. Branden is the qualifying contractor on Sunrise’s CSLB-licensed C-10 (Electrical) classification, license #C10-1097237, and has owned and operated Sunrise since July 2022, serving Santa Cruz County — Davenport to Pajaro Dunes. We replace roughly 15–25 FPE-equipped panels a year and have documentation processes that work cleanly with the major California insurance carriers.

Full profile

Sources

  1. [1]U.S. Consumer Product Safety Commission — recall database searchThe authoritative place to check whether a specific panel or breaker model has been recalled. Recall status attaches to particular products and dates, not to brand names.accessed 2026-08-03
  2. [2]California Electrical Code (Title 24, Part 3) — 2025 edition, effective January 1 20262023 NEC base with California amendments; existing installations are generally permitted to remain as legally installed, which is separate from whether they remain a good idea.accessed 2026-08-03
  3. [3]Santa Cruz County Building Division — permit authorityUnincorporated county, including Live Oak, Pleasure Point, Soquel, Aptos and Felton.accessed 2026-08-03
12·One more thing

Send us a photo of the label.

We will tell you what you have, whether breakers are still obtainable, and whether it is the panel or your plans that should decide the timing.

Toggle the optional categories. Choices saved here persist for a year.

Essential cookies can't be disabled — they keep the site working.